快速检索:        
    
在线办公系统
在线期刊
下载专区
排行榜
友情链接
扫描微信二维码,获取更多信息
李爱华,龚开政,严俊峰,孙晓宁,凤以良,张振刚.疏血通在防治冠脉内支架植入术后再狭窄中的作用[J].中国中西医结合杂志,2004,(10):879-881
疏血通在防治冠脉内支架植入术后再狭窄中的作用
Effect of Shuxuetong in Preventing Restenosis after Intracoronary Stenting
免费下载全文  查看/发表评论  下载PDF阅读器
  
DOI:
中文关键词:  血管成形术  支架置入术  再狭窄  疏血通
英文关键词:angioplasty  stenting  restenosis  Shuxuetong
基金项目:
作者单位
李爱华 江苏省扬州市第一人民医院心血管内科 
龚开政 江苏省扬州市第一人民医院心血管内科 
严俊峰 江苏省扬州市第一人民医院心血管内科 
孙晓宁 江苏省扬州市第一人民医院心血管内科 
凤以良 江苏省扬州市第一人民医院心血管内科 
张振刚 扬州大学医学院临床医学系 
摘要点击次数: 1595
全文下载次数: 1064
中文摘要:
      目的评价疏血通预防冠状动脉内支架植入术后再狭窄的作用。方法 68例完成冠脉内支架植入术的患者在给予常规治疗的基础上 ,随机分为常规治疗对照组和疏血通治疗组。随访观察 6个月 ,采用定量冠状动脉造影的方法对比观察两组患者冠脉病变的再狭窄情况。结果共有 4 3例患者完成随访 ,疏血通治疗组 2 3例 ,常规治疗组 2 0例。疏血通治疗组心绞痛复发率〔3例 ( 1 3%)〕明显低于常规治疗组〔7例( 35 %)〕(P <0 0 5 )。定量冠状动脉造影结果显示 ,疏血通治疗组经治血管的病变狭窄程度明显轻于常规治疗组 ;晚期丢失内径及其指数〔( 0 4 6± 0 2 5 )mm ,( 2 4 2 6± 8 64 ) %〕显著小于常规治疗组〔( 0 75± 0 33)mm ,( 31 2 5± 1 1 0 3) %〕 ,P值均 <0 0 5 ;而净获得内径及其指数〔( 1 2 3± 0 30 )mm ,( 5 8 96± 2 4 68) %〕明显大于常规治疗组〔( 0 98± 0 33)mm ,( 42 68± 2 9 5 1 ) %〕 ,P值均 <0 0 5。两组患者的再狭窄率比较无显著性差异 (P >0 0 5 )。结论疏血通在预防冠脉内支架植入术后再狭窄中可能具有一定作用。
英文摘要:
      Objective To evaluate the effect of Shuxuetong (SXT) in preventing restenosis after intracoronary stenting. Methods Sixty eight patients, accepted intracoronary stenting, were divided into two groups, the SXT group and the control group, both of them were treated with conventional treatment, and to the SXT group, SXT was given additionally. The condition of treated coronary artery restenosis in the two groups was compared by way of quantitative coronary angiography and a 6 month follow up study was adopted. Results Follow up study was completed in 43 patients (23 cases in the SXT group, and 20 in the control group). The angina recurrence rate in the SXT group (3 cases, 13%) was significantly lower than that in the control group (7 cases, 35%, P<0.05). Quantitative coronary angiography showed the restenosis degree of operated artery in the SXT group was significantly milder than that in the control group, with the last lumen losing and index in the SXT group (0 46±0 25 mm, 24 26±8 64%) less than those in the control group (0 75±0 33 mm, 31 25±11 03%). The net gain lumen and the net gain index in the SXT group (1 23±0 30 mm, 58 96±24 68%) were greater than those in the control group (0 98±0 33 mm, 42 68±29 51%), all P<0.05. But the restenosis rate in the two groups was insignificantly different (P>0.05). Conclusion SXT might has some definite effect in preventing restenosis after intracoronary stenting.
关闭